Availability: | |
---|---|
Quantity: | |
Device model | BEP-5KS |
Rated power | 5kW |
Power grid measurement indicators | |
Rated Power | 5kW |
Power Voltage | AC 230V |
Grid Frequency Range | 50Hz/60Hz |
Maximum output current | 25A |
Load side indicators | |
Rated Power | 5kW |
The output voltage | AC 230V±2% |
Maximum output current | 25A |
Output Frequency | 50Hz/60Hz±0.2% |
Photovoltaic Side Indicators | |
MPPT Work Scope | DC 125V-500V |
Starting Voltage | DC 125V |
Maximum Input Current | 13A |
Number of MPPT channels | 2 way |
Battery side indicators | |
Rated voltage | DC 48V |
Maximum charging voltage | DC ≤60V |
Maximum charging current | 120A |
Voltage Range | DC 40V-60V (with battery maintenance function, can charge the battery to 0V) |
System Performance | |
Maximum conversion efficiency (PV) | 97.6% |
Maximum conversion efficiency (battery) | 94.5% |
Switching Time | ≤10ms |
Protective Function | Reverse polarity protection, short circuit, overvoltage, overcurrent, ground fault, etc. |
Usage environment | |
Working Environment | Ambient temperature -20℃-60℃, relative humidity 0-95% |
Protection level | IP65 (Outdoor) |
Cooling method | Fan forced air cooling |
Altitude | ≤6000m (over 2000m, derating is required) |
Other properties | |
Topology | High frequency isolation (battery side) |
Noise | ≤25dB(A) |
Size(W*D*H) | 423*543*190mm |
Device model | BEP-5KS |
Rated power | 5kW |
Power grid measurement indicators | |
Rated Power | 5kW |
Power Voltage | AC 230V |
Grid Frequency Range | 50Hz/60Hz |
Maximum output current | 25A |
Load side indicators | |
Rated Power | 5kW |
The output voltage | AC 230V±2% |
Maximum output current | 25A |
Output Frequency | 50Hz/60Hz±0.2% |
Photovoltaic Side Indicators | |
MPPT Work Scope | DC 125V-500V |
Starting Voltage | DC 125V |
Maximum Input Current | 13A |
Number of MPPT channels | 2 way |
Battery side indicators | |
Rated voltage | DC 48V |
Maximum charging voltage | DC ≤60V |
Maximum charging current | 120A |
Voltage Range | DC 40V-60V (with battery maintenance function, can charge the battery to 0V) |
System Performance | |
Maximum conversion efficiency (PV) | 97.6% |
Maximum conversion efficiency (battery) | 94.5% |
Switching Time | ≤10ms |
Protective Function | Reverse polarity protection, short circuit, overvoltage, overcurrent, ground fault, etc. |
Usage environment | |
Working Environment | Ambient temperature -20℃-60℃, relative humidity 0-95% |
Protection level | IP65 (Outdoor) |
Cooling method | Fan forced air cooling |
Altitude | ≤6000m (over 2000m, derating is required) |
Other properties | |
Topology | High frequency isolation (battery side) |
Noise | ≤25dB(A) |
Size(W*D*H) | 423*543*190mm |
SINJI mainly sells vanadium battery system, reactor, vanadium electrolyte and perfluoride ion membrane.